Vista de página 3
4 | P a g e E P M . d o c , R e v . B , VP, 6 / 12/ 2 0 12
Tel: (800) 404-0204
www.ironwoodelectronics.com
Figure 4: Incorrect way of applying epoxy
1. After epoxy cures, remove the alignment plate.
2. Place elastomer inside the socket base cavity (direction and orientation are critical).
3. Place IC package and compression plate into the socket base cavity.
4. Assemble socket lid onto socket base with socket lid screws.
5. Assemble compression screw into socket lid and apply recommended torque, preferably using the torque
driver tool.